Technical triage

Ice machine making cloudy ice — Rustenburg

Diagnosis, likely causes and safe checks for commercial ice machines showing this symptom, plus the point at which a technician should take over.

RTB // TECHNICAL TRIAGE

RTB-FLT.01 // CAUSES

Possible Causes

LIKELY CAUSES, MOST COMMON FIRST

  • 01High mineral content in the water
  • 02Exhausted filtration
  • 03Scale in the water circuit
  • 04Short freeze cycle

SAFE BASIC CHECKS

  • 01Check filter age and rated volume
  • 02Compare with ice from another machine on site
RTB-FLT.02 // ESCALATE

When Professional Assistance Is Required

STOP AND CALL A TECHNICIAN IF

  • 01Cloudiness persisting after descaling and a filter change

SAFETY

Never work on live electrical components, never open the refrigerant circuit, never attempt compressor repairs, and do not dismantle a commercial machine to reach internal parts. If there is water near electrical equipment or a burning smell, isolate the machine at the wall first.